X-ray Scattering Facility
[insert tag line here]
X-ray Scattering Facility
[insert tag line here]
X-ray Scattering Facility
Menu
Services / User Fees
The X-ray Scattering Facility offers the following services for a fee:
Note. User fees are charged to help offset some of the costs associated with operating and maintaining the core facility. The funds generated by these fees are key to allowing the network of core facilities within NUCLEUS to effectively support research.
Powder X-ray Diffraction (PXRD)
| Service | *Departmental Rate | Internal/External Academic Rate | Industry Rate |
|
|---|---|---|---|---|
| Assisted services include sample preparation and data processing. Data collection is not included. | ||||
| Qualitative phase analysis | 1-2 phases | $25/sample | $50/sample | $75/sample |
| 3-4 phases | $50/sample | $100/sample | $150/sample | |
| >4 phases | $100/sample | $150/sample | $250/sample | |
| Quantitative phase analysis1 | $50/sample | $100/sample | $150/sample | |
| Indexing2 | $50/sample | $75/sample | $120/sample | |
| Rietveld refinement3 | $100/sample | $150/sample | $250/sample | |
| Ab initio structure determination4 | $300/sample | $400/sample | $500/sample | |
| Crystallite size | $50/sample | $100/sample | $150/sample | |
| Texture (rocking curves, pole figures) | $80/sample | $120/sample | $180/sample | |
| Thermal expansion (VT)5 | Analysis | $10/per point | $15/per point | $30/per point |
| Setup | $20 | $40 | $50 | |
| Phase diagrams (VT-VP)6 | Processing | $10/per point | $15 per/point | $30/per point |
| Setup | $20 | $40 | $50 | |
| High throughput/Clusters7 | Analysis | $50 | $100 | $150 |
| High resolution illustrations for publications | Free | $15/image | $40/image | |
| Data acquisition only | ||||
| Proto AXRD Benchtop8 | Unassisted | Variable rate | $50/hr | $100/hr |
| Proto LPD-HTS9 | Assisted | $100/hr | $150/hr | $200/hr |
| Bruker D8 DISCOVER10 | Unassisted | Variable rate | $50/hr | $100/hr |
| High temperature | Unassisted | Variable rate | +$10/hr | +$30/hr |
| (298-773K)11 | Assisted | Variable rate | +$10/hr | +$30/hr |
| Low temperature | Unassisted | Variable rate | +$20/hr | +$40/hr |
| (80-400K)12 | Assisted | Variable rate | +$20/hr | +$40/hr |
| Variable pressure (<30 bar)13 | Assisted | Variable rate | +$20/hr | +$40/hr |
Service Notes
- * Rates for users from the Department of Chemistry and Biochemistry at the University of Windsor.
- 1 When analysis is performed on the phases provided by the client. In case no phases are provided, fees for the qualitative phase analysis will be added to the final bill.
- 2 The list of potential unit cells with presumable space groups ranked based on the LeBail iterative integration.
- 3 Starting structural model should be provided.
- 4 This service includes indexing, structure solution and Rietveld refinement. Client might need to supply chemical information and spectroscopical data to validate the results of structure determination.
- 5 Service includes quick indexing with LeBail iterative algorithm. Phase must be known. The fee is specified per experimental point. E.g., 5 points = 5 x $10 = $50.
- 6 Available gases: nitrogen, carbon dioxide.
- 7 Only available for data collected on Proto LPD-HTS. Service includes analysis of similarity/dissimilarity including with distance matrices, dendrograms and principal component analysis.
- 8 Data acquisition rate is capped at $200/sample for Rietveld refinement and structure determination services.
- 9 Data acquisition rate is capped at $200/sample for Rietveld refinement and structure determination services.
- 10 Data acquisition rate is capped at $200/sample for Rietveld refinement and structure determination services.
- 11 30-50 mg of the sample is needed. Data is collected on Proto AXRD Benchtop equipped with Anton Paar BTS500. The fee is additive to the data acquisition rate for the corresponding instrument.
- 12 10-20 mg of the sample is needed. Unassisted data collection is available only for Bruker D8 DISCOVER. Data can be collected by facility manager on Proto LPD-HTS equipped with Oxford Cryosystems Cobra open-flow chiller. The fee is additive to the data acquisition rate for the corresponding instrument.
- 13 10-20 mg of the sample is needed. Data is collected on Proto LPD-HTS equipped with a high-pressure capillary stage. The fee is additive to the data acquisition rate for the corresponding instrument.
Single Crystal X-ray Diffraction (SC-XRD)
| Service | *Departmental Rate | Internal/External Academic Rate | Industry Rate |
|---|---|---|---|
| Unit cell determination | $25/sample | $35/sample | $60/sample |
| Data collection (up to 6 hours) | $75/sample | $150/sample | $300/sample |
| Complete data collection and structure determination | $120/sample | $250/sample | $500/sample |
| Data collection (more than 6 hours) | Variable rate | +$10/hr | +$30/hr |
| Data collection (temperature <100K) | Variable rate | +$35 | +$75 |
Service Notes
- * Rates for users from the Department of Chemistry and Biochemistry at the University of Windsor.
- External Academic Users (non-UWindsor) and Industry Users do not have unassisted access to the SC-XRD instrumentation. Specified prices for assisted services include 1 hour of crystal harvesting and mounting. In case extra time is required to find and mount a suitable crystal, additional fee of $75/hour will be applied.
User Training
| Service | *Departmental Rate | Internal/External Academic Rate | Industry Rate |
|
|---|---|---|---|---|
| PXRD | Basic training (40 min) | $30 | $75 | $100 |
| SC-XRD | Basic training (1 hr) | $50 | $75 | n/a |
| Comprehensive crystallographic training (3 x 2 hr sessions) | $500 | $750 | $1,000 | |
Service Notes
- * Rates for users from the Department of Chemistry and Biochemistry at the University of Windsor.
- External Academic Users (non-UWindsor) and Industry Users do not have unassisted access to the SC-XRD instrumentation.
- See Core Resources > Training Requirements for more details on user training for the equipment in the X-ray Scattering Core.
Consultation
| Service | *Departmental Rate | Internal/External Academic Rate | Industry Rate |
|
|---|---|---|---|---|
| Crystallographer’s consult | $75/hr | $75/hr | $75/hr | |
Service Notes
- * Rates for users from the Department of Chemistry and Biochemistry at the University of Windsor.
Powder X-ray Diffraction (PXRD)
| Service | *Departmental Rate | Internal/External Academic Rate | Industry Rate |
|
|---|---|---|---|---|
| Assisted services include sample preparation and data processing. Data collection is not included. | ||||
| Qualitative phase analysis | 1-2 phases | $25/sample | $50/sample | $75/sample |
| 3-4 phases | $50/sample | $100/sample | $150/sample | |
| >4 phases | $100/sample | $150/sample | $250/sample | |
| Quantitative phase analysis1 | $50/sample | $100/sample | $150/sample | |
| Indexing2 | $50/sample | $75/sample | $120/sample | |
| Rietveld refinement3 | $100/sample | $150/sample | $250/sample | |
| Ab initio structure determination4 | $300/sample | $400/sample | $500/sample | |
| Crystallite size | $50/sample | $100/sample | $150/sample | |
| Texture (rocking curves, pole figures) | $80/sample | $120/sample | $180/sample | |
| Thermal expansion (VT)5 | Analysis | $10/per point | $15/per point | $30/per point |
| Setup | $20 | $40 | $50 | |
| Phase diagrams (VT-VP)6 | Processing | $10/per point | $15 per/point | $30/per point |
| Setup | $20 | $40 | $50 | |
| High throughput/Clusters7 | Analysis | $50 | $100 | $150 |
| High resolution illustrations for publications | Free | $15/image | $40/image | |
| Data acquisition only | ||||
| Proto AXRD Benchtop8 | Unassisted | Variable rate | $50/hr | $100/hr |
| Proto LPD-HTS9 | Assisted | $100/hr | $150/hr | $200/hr |
| Bruker D8 DISCOVER10 | Unassisted | Variable rate | $50/hr | $100/hr |
| High temperature | Unassisted | Variable rate | +$10/hr | +$30/hr |
| (298-773K)11 | Assisted | Variable rate | +$10/hr | +$30/hr |
| Low temperature | Unassisted | Variable rate | +$20/hr | +$40/hr |
| (80-400K)12 | Assisted | Variable rate | +$20/hr | +$40/hr |
| Variable pressure (<30 bar)13 | Assisted | Variable rate | +$20/hr | +$40/hr |
Service Notes
- * Rates for users from the Department of Chemistry and Biochemistry at the University of Windsor.
- 1 When analysis is performed on the phases provided by the client. In case no phases are provided, fees for the qualitative phase analysis will be added to the final bill.
- 2 The list of potential unit cells with presumable space groups ranked based on the LeBail iterative integration.
- 3 Starting structural model should be provided.
- 4 This service includes indexing, structure solution and Rietveld refinement. Client might need to supply chemical information and spectroscopical data to validate the results of structure determination.
- 5 Service includes quick indexing with LeBail iterative algorithm. Phase must be known. The fee is specified per experimental point. E.g., 5 points = 5 x $10 = $50.
- 6 Available gases: nitrogen, carbon dioxide.
- 7 Only available for data collected on Proto LPD-HTS. Service includes analysis of similarity/dissimilarity including with distance matrices, dendrograms and principal component analysis.
- 8 Data acquisition rate is capped at $200/sample for Rietveld refinement and structure determination services.
- 9 Data acquisition rate is capped at $200/sample for Rietveld refinement and structure determination services.
- 10 Data acquisition rate is capped at $200/sample for Rietveld refinement and structure determination services.
- 11 30-50 mg of the sample is needed. Data is collected on Proto AXRD Benchtop equipped with Anton Paar BTS500. The fee is additive to the data acquisition rate for the corresponding instrument.
- 12 10-20 mg of the sample is needed. Unassisted data collection is available only for Bruker D8 DISCOVER. Data can be collected by facility manager on Proto LPD-HTS equipped with Oxford Cryosystems Cobra open-flow chiller. The fee is additive to the data acquisition rate for the corresponding instrument.
- 13 10-20 mg of the sample is needed. Data is collected on Proto LPD-HTS equipped with a high-pressure capillary stage. The fee is additive to the data acquisition rate for the corresponding instrument.
Single Crystal X-ray Diffraction (SC-XRD)
| Service | *Departmental Rate | Internal/External Academic Rate | Industry Rate |
|---|---|---|---|
| Unit cell determination | $25/sample | $35/sample | $60/sample |
| Data collection (up to 6 hours) | $75/sample | $150/sample | $300/sample |
| Complete data collection and structure determination | $120/sample | $250/sample | $500/sample |
| Data collection (more than 6 hours) | Variable rate | +$10/hr | +$30/hr |
| Data collection (temperature <100K) | Variable rate | +$35 | +$75 |
Service Notes
- * Rates for users from the Department of Chemistry and Biochemistry at the University of Windsor.
- External Academic Users (non-UWindsor) and Industry Users do not have unassisted access to the SC-XRD instrumentation. Specified prices for assisted services include 1 hour of crystal harvesting and mounting. In case extra time is required to find and mount a suitable crystal, additional fee of $75/hour will be applied.
User Training
| Service | *Departmental Rate | Internal/External Academic Rate | Industry Rate |
|
|---|---|---|---|---|
| PXRD | Basic training (40 min) | $30 | $75 | $100 |
| SC-XRD | Basic training (1 hr) | $50 | $75 | n/a |
| Comprehensive crystallographic training (3 x 2 hr sessions) | $500 | $750 | $1,000 | |
Service Notes
- * Rates for users from the Department of Chemistry and Biochemistry at the University of Windsor.
- External Academic Users (non-UWindsor) and Industry Users do not have unassisted access to the SC-XRD instrumentation.
- See Core Resources > Training Requirements for more details on user training for the equipment in the X-ray Scattering Facility.
Consultation
| Service | *Departmental Rate | Internal/External Academic Rate | Industry Rate |
|
|---|---|---|---|---|
| Crystallographer’s consult | $75/hr | $75/hr | $75/hr | |
Service Notes
- * Rates for users from the Department of Chemistry and Biochemistry at the University of Windsor.